VPD Calculator (Vapor Pressure Deficit)

Calculate leaf and air vapor pressure deficit from air temperature, relative humidity and leaf temperature, with a color-banded VPD chart for propagation, vegetative and flowering stages.

Last updatedHow we build & check our tools
C
%
C
Results will appear here once you enter your values.

What vapor pressure deficit measures

Relative humidity tells you how full the air is as a percentage, but plants respond to how hard the air pulls water out of the leaf. That pull is the vapor pressure deficit (VPD): the gap between how much water vapor the air could hold at saturation and how much it actually holds, measured in kilopascals (kPa). The same 60% humidity is gentle at 18 C (VPD about 0.83 kPa) and much drier at 30 C (about 1.70 kPa), because warm air can hold far more vapor.

This calculator finds saturation vapor pressure with the Tetens equation used in FAO-56: e° = 0.6108 x exp(17.27T / (T + 237.3)), with T in Celsius. At 25 C that gives 3.168 kPa. Air VPD is e°(air) x (1 - RH/100), so 25 C at 60% humidity is 1.27 kPa.

Why leaf temperature changes the answer

Stomata sit inside the leaf, where the air is saturated at leaf temperature, not room temperature. Leaf VPD is therefore e°(leaf) minus the actual vapor pressure of the room. Transpiration cools leaves, so under LED fixtures they commonly run 1 to 3 C below air temperature. With a 2 C cooler leaf, the 25 C and 60% room drops from 1.27 kPa of air VPD to about 0.91 kPa of leaf VPD, which moves the plant from the late-vegetative band into early vegetative.

  • Measure leaf surface temperature with an infrared thermometer at canopy height, a few leaves deep.
  • High-pressure sodium lamps heat leaves, so the offset can be 0 or even positive.
  • A negative leaf VPD means the leaf is below the dew point of the air, and water will condense on it.

Reading the VPD chart by growth stage

Growers target a range rather than a single number. Common guideline bands are 0.4 to 0.8 kPa for unrooted cuttings and seedlings, 0.8 to 1.2 kPa for early vegetative growth, 1.2 to 1.5 kPa for late veg and early flower, and 1.5 to 1.6 kPa late in flower, when drier air helps prevent bud rot. These are horticultural rules of thumb, and species differ: leafy greens often do best near 0.8 kPa, while tomatoes tolerate 1.0 to 1.5 kPa.

Below about 0.4 kPa, transpiration nearly stops, calcium delivery to new growth suffers, and fungal pathogens such as botrytis and powdery mildew thrive. Above about 1.6 kPa, many plants partly close their stomata to save water, which also cuts CO2 uptake and slows growth. To lower VPD, raise humidity or lower temperature; to raise it, dehumidify or add a little heat.

Common VPD mistakes

Most bad VPD readings come from the inputs, not the math.

  • Using air VPD when charts assume leaf VPD. Check which one a target chart uses; a 2 C offset shifts the result by 0.3 kPa or more.
  • Sensor placement. A hygrometer near the ceiling or a humidifier can be off by 10% RH from the canopy, which is roughly 0.3 kPa at 25 C.
  • Chasing one number all day. VPD swings when lights switch off. Aim for the band during the light period and avoid condensation at lights-off.

Frequently Asked Questions

Common questions about the VPD Calculator (Vapor Pressure Deficit)

Most growers aim for about 0.8 to 1.2 kPa of leaf VPD during vegetative growth. Seedlings and clones prefer 0.4 to 0.8 kPa, and late flowering stages run drier at about 1.2 to 1.6 kPa.

Sources & References

FAO Irrigation and Drainage Paper 56, Chapter 3: Meteorological data

Saturation vapor pressure (Tetens) equation, actual vapor pressure from relative humidity, and the vapor pressure deficit definition.

Vapor Pressure calculation notes

Saturation and actual vapor pressure formulas from temperature, dew point and relative humidity.